Comparison between Multi-Variable Differential Pressure Transmitter (ALDPT-MV) , Standard Vortex Flow Meter (ALVT), VORTEX MASS VORTEX FLOW METER (ALVT-MASS)
Name
Multi-Variable Differential Pressure Transmitter (ALDPT-MV)
Standard Vortex Flow Meter (ALVT)
VORTEX MASS VORTEX FLOW METER (ALVT-MASS)
Price
Contact Us For Price
Contact Us For Price
Contact Us For Price
Category
Differential Pressure Flowmeter
Vortex Flowmeter
Vortex Flowmeter
Sizes
Any
-12" (15-300 mm)
-12" (15-300 mm)
Accuracy
±0.2%, ±0.075% of reading
1.5% gas/steam, 1% liquids
1.5% gas/steam, 1% liquids
Process Temperature
4-752°F(-20- 400)°C
Temperature
-23~482 °F ( -5 ~ +250 °C)
-23~482 °F ( -5 ~ +250 °C)
Process Connection
Flanges (ANSI, DIN & JIS), Wafer
Flanges (ANSI, DIN & JIS), Wafer
Application
Where multiple parameter measurement such as flow, DP, temperature, mass flow is required from one instrument
Best solution for steam, limited liquid and gas applications
Best solution for steam, limited liquid and gas applications
Styles
Multi-variable Differential Pressure
Measuring range
Based on DP of 0 -2Mpa (290 PSI)
Viscosity
1 to 10 cSt
1 to 10 cSt
Metering tube
SS #316L, Hastelloy C, Tantalum
Outputs & Electronics
4~20 mA square root output, HART, MODBUS
Connection
“-18 NPTF & "-20 UNF, no drain or with drain top, side or bottom of flange
Operating Pressure
Up to 920 psi (6.4MPa)
Up to 920 psi (6.4MPa)
Material
SS #304 (standard) SS #316 (optional)
SS #304 (standard) SS #316 (optional)
Signal Output
4-20mA, pulse, Modbus, HART
4-20mA, pulse, Modbus, HART
Process Medium
3 or 5-way valve manifold for primary DP flow element (ACONE), 2" pipe mounting brackets, O2 cleaning, capillaries (many fill fluids)
Steam, liquid, gas
Steam, liquid, gas