Comparison between Economical Transit-Time Ultrasonic Flow Meter [ALSONIC-FX], Graphic Multi-Channel Permanent Ultrasonic Meter [ALSONIC-DSP], Doppler Technology Ultrasonic Meter [ALSONIC-DDPL], Low flow Small size Ultrasonic Flow Meter (ALSONIC-MINI)
Name
Economical Transit-Time Ultrasonic Flow Meter [ALSONIC-FX]
Graphic Multi-Channel Permanent Ultrasonic Meter [ALSONIC-DSP]
Doppler Technology Ultrasonic Meter [ALSONIC-DDPL]
Low flow Small size Ultrasonic Flow Meter (ALSONIC-MINI)
Price
Contact Us For Price
Contact Us For Price
Contact Us For Price
Contact Us For Price
Category
PERMANENT INSTALL CLAMP-ON ULTRASONIC FLOW METERS
PERMANENT INSTALL CLAMP-ON ULTRASONIC FLOW METERS
PERMANENT INSTALL CLAMP-ON ULTRASONIC FLOW METERS, PORTABLE CLAMP-ON ULTRASONIC METERS
PORTABLE CLAMP-ON ULTRASONIC METERS
Sizes
1/2"-48" (15-12000 mm)
3/4"-240" (20-6000 mm)
1/2" - 240" (15-6000 mm)
1/2"-2" (15-50 mm)
Accuracy
1% - 2% of reading
0.5% - 1% of reading
2% - 5% of reading
2% of reading
Temperature
-22~+230 °F (-30 ~ +110C)
-22~+248 °F (-30 ~ +120C)
-22~+302 °F (-30 ~ +150C)
32~+122 °F ( -0 ~ +50C)
Application
Water, factory automation, HVAC
Oil & gas, water, wastewater, marine, power/utility
Wastewater, drilling mud, any portable application with many particles
Chemical, DI-water, corrosive fluids
Styles
Wall-mount, economical
Single or dual channel, graphic display
Wall mount, Doppler technology
Plug & play transducers
Medium
Clean liquids; ≤1-2 % bubbles / particulates
Any liquid w/ ≤30% bubbles / particulates
Liquid must be dirty with some particles
Clean liquids
Function
Single channel measurement; ,MODBUS, analog & pulse outputs, 16G SD data logger
Dual channel, Oscilloscope function, MODBUS, 2 analog inputs/outputs, internal data logger
Analog/digital outputs, data logger
Plug and play transducers, no gell needed