Comparison between VEGAPULS 6X , VEGABAR 81 - With chemical seal, for high temperatures, VEGABAR 82 - Universally applicable pressure transmitter, VEGABAR 83 - Metallic Pressure Transmitter

Selected Product
VEGAPULS 6X

VEGAPULS 6X

VEGABAR 81 - With chemical seal, for high temperatures

VEGABAR 81 - With chemical seal, for high temperatures

 VEGABAR 82 - Universally applicable pressure transmitter

VEGABAR 82 - Universally applicable pressure transmitter

VEGABAR 83 - Metallic Pressure Transmitter

VEGABAR 83 - Metallic Pressure Transmitter

Name

VEGAPULS 6X

VEGABAR 81 - With chemical seal, for high temperatures

VEGABAR 82 - Universally applicable pressure transmitter

VEGABAR 83 - Metallic Pressure Transmitter

Price

Contact Us For Price

Contact Us For Price

Contact Us For Price

Contact Us For Price

Category

Radar Level Transmitter (VEGA)

Pressure Transmitter - Process Pressure (VEGA)

Pressure Transmitter - Process Pressure (VEGA)

Pressure Transmitter - Process Pressure (VEGA)

Radar sensor for continuous level measurement of liquids and bulk solids

All-round radar instrument

Accuracy


± 1 mm


0.2 %


0.05 %


0.075 %

Measuring range - Distance


120m

Process Temperature


-196 ... 450 °C


-90 ... 400 °C


-40 ... 150 °C


-40 ... 200 °C

Process Pressure


-1 ... 160 bar


-1 ... 1000 bar


-1 ... 100 bar


-1 ... 1000 bar

Materials, wetted parts


- PTFE
- PVDF
- 316L
- PP
- PEEK


- Alloy C22 (2.4602)
- Alloy 400 (2.4360)
- Tantalum
- Alloy C276 (2.4819)
- Duplex (1.4462)
- Titanium Grade 2 (3.7035)
- 1.4435
- 316/316L
- Titanium Grade 7 (3.7235)


- PVDF
- 316L
- Alloy C22 (2.4602)
- PP
- 1.4057
- 1.4410
- Alloy C276 (2.4819)
- Duplex (1.4462)
- Titanium Grade 2 (3.7035)


- 316L
- Alloy C22 (2.4602)
- 316Ti (1.4571)
- Alloy C4 (2.4610)

Threaded connection


≥ G, ≥ NPT


≥ G, ≥ NPT


≥ G, ≥ NPT


≥ G, ≥ NPT

Protection rating


- IP66/IP68 (0,2 bar)
- IP66/IP67
- IP66/IP68 (1 bar)
- IP69K


- IP66/IP68 (0,2 bar)
- IP66/IP67
- IP66/IP68 (1 bar)
- IP66/IP68 (25 bar)
- IP69K


- IP66/IP68 (0,2 bar)
- IP66/IP67
- IP66/IP68 (1 bar)
- IP66/IP68 (25 bar)
- IP69K


- IP66/IP67
- IP66/IP68 (1 bar)
- IP68 (0,2 bar)
- IP66/IP68 (25 bar)
- IP69K

Output


- Profibus PA
- Foundation Fieldbus
- 4 … 20 mA
- 4 … 20 mA/HART - two-wire
- Modbus
- Secondary electronics for electronic differential pressure


- Profibus PA
- Foundation Fieldbus
- 4 … 20 mA
- 4 … 20 mA/HART - two-wire
- Modbus
- Secondary electronics for electronic differential pressure


- Profibus PA
- Foundation Fieldbus
- 4 … 20 mA
- 4 … 20 mA/HART - two-wire
- Modbus
- Secondary electronics for electronic differential pressure

Ambient temperature


-40 ... 80 °C


-40 ... 80 °C


-40 ... 80 °C


-40 ... 80 °C

Display & adjustment

- PLICSCOM
- PC, PACTware and DTM
- HART-Communicator
- Software (e. g. AMS, PDM)
- Bluetooth


- PLICSCOM
- PC, PACTware and DTM
- HART-Communicator
- Software (e. g. AMS, PDM)


- PLICSCOM
- PC, PACTware and DTM
- HART-Communicator
- Software (e. g. AMS, PDM)


- PLICSCOM
- PC, PACTware and DTM
- HART-Communicator
- Software (e. g. AMS, PDM)

Seal Material


- EPDM
- FKM
- FFKM
- graphit and ceramic
- PTFE


no media contact


- EPDM
- FKM
- FFKM


no media contact

Housing Material


- Plastic
- Aluminium
- Stainless steel (precision casting)
- Stainless steel (electropolished)


- Plastic
- Aluminium
- tainless steel (precision casting)
- Stainless steel (electropolished)


- Plastic
- Aluminium
- Stainless steel (precision casting)
- Stainless steel (electropolished)


- Plastic
- Aluminium
- Stainless steel (precision casting)
- Stainless steel (electropolished)

Beam angle


≥ 3°

Frequency


- 6 GHz
- 26 GHz
- 80 GHz

Approvals


- ATEX / Europe
- CSA / Canada
- FM / USA
- EAC (GOST) / Belarus
- EAC (GOST) / Kazakhstan
- EAC (GOST) / Russia
- IEC / worldwide
- KOSHA / Korea
- NEPSI / China
- UKR Sepro / Ukraine
- IEC / Australia
- INMETRO / Brazil
- CCOE / India
- CSA / USA and Canada
- TIIS / Japan


- ATEX / Europe
- CSA / Canada
- FM / USA
- EAC (GOST) / Belarus
- EAC (GOST) / Kazakhstan
- EAC (GOST) / Russia
- IEC / worldwide
- INMETRO / Brazil
- CCOE / India
- CSA / USA and Canada


- ATEX / Europe
- CSA / Canada
- FM / USA
- EAC (GOST) / Belarus
- EAC (GOST) / Kazakhstan
- EAC (GOST) / Russia
- IEC / worldwide
- INMETRO / Brazil
- CCOE / India


- ATEX / Europe
- CSA / Canada
- FM / USA
- EAC (GOST) / Belarus
- EAC (GOST) / Russia
- IEC / worldwide
- INMETRO / Brazil
- CCOE / India
- CSA / USA and Canada

Explosion Protection


- Intrinsic safety "i"
- Flameproof enclosure "d"
- Dust explosion protection through housing "t"


- Intrinsic safety "i"
- Flameproof enclosure "d"
- Dust explosion protection through housing "t"


- Intrinsic safety "i"
- Flameproof enclosure "d"
- Dust explosion protection through housing "t"


- Intrinsic safety "i"
- Flameproof enclosure "d"
- Dust explosion protection through housing "t"

Ship Approval


Ship approval


- ABS
- BV
- CCS
- DNV
- GL
- LR
- RINA


- ABS
- BV
- CCS
- DNV
- GL
- LR
- RINA


- ABS
- BV
- CCS
- DNV
- GL
- LR
- RINA

Flange connection


≥ DN20, ≥ "


≥ DN25, ≥ 1"


≥ DN15, ≥ "


≥ DN25, ≥ 1"

Foodstuffs/Pharma


Foodstuffs/Pharma


- FDA
- EG1935/2004


- 3A
- EHEDG
- FDA
- Drinking water
- EG1935/2004


- 3A
- EHEDG
- FDA
- EG1935/2004

Overfill protection


- WHG
- VLAREM II


- WHG
- VLAREM II


- WHG
- VLAREM II


- WHG
- VLAREM II

SIL qualification


SIL qualification


SIL2


SIL2


SIL2

Measuring range - Pressure


-1 ... 1000 bar


-1 ... 100 bar


-1 ... 1000 bar

Hygenic fittings


- Clamp ≥ 1" - DIN32676, ISO2852
- Slotted nut ≥ 2", DN50 - DIN 11851
- Varivent ≥ DN25
- hygienic fitting with tension flange DN32
- hygienic fitting F40 with compression nut
- Hygienic screw connections ≥ DN50 tube 53 - DIN11864-1-A
- Hygienice flange connection ≥ DN50 DIN11864-2
- Hygienic clamp connection ≥ DN50 pipe 53 - DIN11864-3-A
- DRD connection 65 mm
- SMS 1145 DN51


- Clamp ≥ 1" - DIN32676, ISO2852
- Slotted nut ≥ 1", ≥ DN40 - DIN 11851
- Hygienic fitting with tension flange DN32
- Hygienic fitting F40 with compression nut
- Hygienic flange connection ≥ DN50 DIN11864-2
- Hygienic fittings ≥ DN40 - DIN11864-1-A


- Clamp ≥ 1" - DIN32676, ISO2852
- Slotted nut ≥ DN25 - DIN 11851
- hygienic fitting with tension flange DN32
- hygienic fitting F40 with compression nut
- DRD connection 65 mm
- SMS 1145 DN51
- SMS DN38
- Swagelok VCR screwing
- Varivent G125
- Varivent N50-40
- for NEUMO BioControl D50 PN16 / 316L


- Slotted nut ≥ DN25 - DIN 11851
- Varivent ≥ DN25
- hygienic fitting with tension flange DN32
- Hygienice flange connection ≥ DN50 DIN11864-2
- SMS 1145 DN51
- SMS DN38
- Hygienic fittings ≥ DN33 - DIN11864-1-A
- Hyg. collar clamp adapter DN40PN40 DIN11864-3-A
- Hyg. clamp connection DIN11864-3-A; DN50 Rohr 53
- Swagelok VCR screwing
- Varivent G125

Indication


- Display/adjustment module PLICSCOM
- VEGADIS 81
- VEGADIS 82


- Display/adjustment module PLICSCOM
- VEGADIS 81
- VEGADIS 82


- Display/adjustment module PLICSCOM
- VEGADIS 81
- VEGADIS 82


- Display/adjustment module PLICSCOM
- VEGADIS 81
- VEGADIS 82