Comparison between VEGAPULS 6X , VEGABAR 81 - With chemical seal, for high temperatures, VEGABAR 82 - Universally applicable pressure transmitter, VEGABAR 83 - Metallic Pressure Transmitter
Name
VEGAPULS 6X
VEGABAR 81 - With chemical seal, for high temperatures
VEGABAR 82 - Universally applicable pressure transmitter
VEGABAR 83 - Metallic Pressure Transmitter
Price
Contact Us For Price
Contact Us For Price
Contact Us For Price
Contact Us For Price
Category
Radar Level Transmitter (VEGA)
Pressure Transmitter - Process Pressure (VEGA)
Pressure Transmitter - Process Pressure (VEGA)
Pressure Transmitter - Process Pressure (VEGA)
Radar sensor for continuous level measurement of liquids and bulk solids
All-round radar instrument
Accuracy
± 1 mm
0.2 %
0.05 %
0.075 %
Measuring range - Distance
120m
Process Temperature
-196 ... 450 °C
-90 ... 400 °C
-40 ... 150 °C
-40 ... 200 °C
Process Pressure
-1 ... 160 bar
-1 ... 1000 bar
-1 ... 100 bar
-1 ... 1000 bar
Materials, wetted parts
- PTFE
- PVDF
- 316L
- PP
- PEEK
- Alloy C22 (2.4602)
- Alloy 400 (2.4360)
- Tantalum
- Alloy C276 (2.4819)
- Duplex (1.4462)
- Titanium Grade 2 (3.7035)
- 1.4435
- 316/316L
- Titanium Grade 7 (3.7235)
- PVDF
- 316L
- Alloy C22 (2.4602)
- PP
- 1.4057
- 1.4410
- Alloy C276 (2.4819)
- Duplex (1.4462)
- Titanium Grade 2 (3.7035)
- 316L
- Alloy C22 (2.4602)
- 316Ti (1.4571)
- Alloy C4 (2.4610)
Threaded connection
≥ G, ≥ NPT
≥ G, ≥ NPT
≥ G, ≥ NPT
≥ G, ≥ NPT
Protection rating
- IP66/IP68 (0,2 bar)
- IP66/IP67
- IP66/IP68 (1 bar)
- IP69K
- IP66/IP68 (0,2 bar)
- IP66/IP67
- IP66/IP68 (1 bar)
- IP66/IP68 (25 bar)
- IP69K
- IP66/IP68 (0,2 bar)
- IP66/IP67
- IP66/IP68 (1 bar)
- IP66/IP68 (25 bar)
- IP69K
- IP66/IP67
- IP66/IP68 (1 bar)
- IP68 (0,2 bar)
- IP66/IP68 (25 bar)
- IP69K
Output
- Profibus PA
- Foundation Fieldbus
- 4 … 20 mA
- 4 … 20 mA/HART - two-wire
- Modbus
- Secondary electronics for electronic differential pressure
- Profibus PA
- Foundation Fieldbus
- 4 … 20 mA
- 4 … 20 mA/HART - two-wire
- Modbus
- Secondary electronics for electronic differential pressure
- Profibus PA
- Foundation Fieldbus
- 4 … 20 mA
- 4 … 20 mA/HART - two-wire
- Modbus
- Secondary electronics for electronic differential pressure
Ambient temperature
-40 ... 80 °C
-40 ... 80 °C
-40 ... 80 °C
-40 ... 80 °C
Display & adjustment
- PLICSCOM
- PC, PACTware and DTM
- HART-Communicator
- Software (e. g. AMS, PDM)
- Bluetooth
- PLICSCOM
- PC, PACTware and DTM
- HART-Communicator
- Software (e. g. AMS, PDM)
- PLICSCOM
- PC, PACTware and DTM
- HART-Communicator
- Software (e. g. AMS, PDM)
- PLICSCOM
- PC, PACTware and DTM
- HART-Communicator
- Software (e. g. AMS, PDM)
Seal Material
- EPDM
- FKM
- FFKM
- graphit and ceramic
- PTFE
no media contact
- EPDM
- FKM
- FFKM
no media contact
Housing Material
- Plastic
- Aluminium
- Stainless steel (precision casting)
- Stainless steel (electropolished)
- Plastic
- Aluminium
- tainless steel (precision casting)
- Stainless steel (electropolished)
- Plastic
- Aluminium
- Stainless steel (precision casting)
- Stainless steel (electropolished)
- Plastic
- Aluminium
- Stainless steel (precision casting)
- Stainless steel (electropolished)
Beam angle
≥ 3°
Frequency
- 6 GHz
- 26 GHz
- 80 GHz
Approvals
- ATEX / Europe
- CSA / Canada
- FM / USA
- EAC (GOST) / Belarus
- EAC (GOST) / Kazakhstan
- EAC (GOST) / Russia
- IEC / worldwide
- KOSHA / Korea
- NEPSI / China
- UKR Sepro / Ukraine
- IEC / Australia
- INMETRO / Brazil
- CCOE / India
- CSA / USA and Canada
- TIIS / Japan
- ATEX / Europe
- CSA / Canada
- FM / USA
- EAC (GOST) / Belarus
- EAC (GOST) / Kazakhstan
- EAC (GOST) / Russia
- IEC / worldwide
- INMETRO / Brazil
- CCOE / India
- CSA / USA and Canada
- ATEX / Europe
- CSA / Canada
- FM / USA
- EAC (GOST) / Belarus
- EAC (GOST) / Kazakhstan
- EAC (GOST) / Russia
- IEC / worldwide
- INMETRO / Brazil
- CCOE / India
- ATEX / Europe
- CSA / Canada
- FM / USA
- EAC (GOST) / Belarus
- EAC (GOST) / Russia
- IEC / worldwide
- INMETRO / Brazil
- CCOE / India
- CSA / USA and Canada
Explosion Protection
- Intrinsic safety "i"
- Flameproof enclosure "d"
- Dust explosion protection through housing "t"
- Intrinsic safety "i"
- Flameproof enclosure "d"
- Dust explosion protection through housing "t"
- Intrinsic safety "i"
- Flameproof enclosure "d"
- Dust explosion protection through housing "t"
- Intrinsic safety "i"
- Flameproof enclosure "d"
- Dust explosion protection through housing "t"
Ship Approval
Ship approval
- ABS
- BV
- CCS
- DNV
- GL
- LR
- RINA
- ABS
- BV
- CCS
- DNV
- GL
- LR
- RINA
- ABS
- BV
- CCS
- DNV
- GL
- LR
- RINA
Flange connection
≥ DN20, ≥ "
≥ DN25, ≥ 1"
≥ DN15, ≥ "
≥ DN25, ≥ 1"
Foodstuffs/Pharma
Foodstuffs/Pharma
- FDA
- EG1935/2004
- 3A
- EHEDG
- FDA
- Drinking water
- EG1935/2004
- 3A
- EHEDG
- FDA
- EG1935/2004
Overfill protection
- WHG
- VLAREM II
- WHG
- VLAREM II
- WHG
- VLAREM II
- WHG
- VLAREM II
SIL qualification
SIL qualification
SIL2
SIL2
SIL2
Measuring range - Pressure
-1 ... 1000 bar
-1 ... 100 bar
-1 ... 1000 bar
Hygenic fittings
- Clamp ≥ 1" - DIN32676, ISO2852
- Slotted nut ≥ 2", DN50 - DIN 11851
- Varivent ≥ DN25
- hygienic fitting with tension flange DN32
- hygienic fitting F40 with compression nut
- Hygienic screw connections ≥ DN50 tube 53 - DIN11864-1-A
- Hygienice flange connection ≥ DN50 DIN11864-2
- Hygienic clamp connection ≥ DN50 pipe 53 - DIN11864-3-A
- DRD connection 65 mm
- SMS 1145 DN51
- Clamp ≥ 1" - DIN32676, ISO2852
- Slotted nut ≥ 1", ≥ DN40 - DIN 11851
- Hygienic fitting with tension flange DN32
- Hygienic fitting F40 with compression nut
- Hygienic flange connection ≥ DN50 DIN11864-2
- Hygienic fittings ≥ DN40 - DIN11864-1-A
- Clamp ≥ 1" - DIN32676, ISO2852
- Slotted nut ≥ DN25 - DIN 11851
- hygienic fitting with tension flange DN32
- hygienic fitting F40 with compression nut
- DRD connection 65 mm
- SMS 1145 DN51
- SMS DN38
- Swagelok VCR screwing
- Varivent G125
- Varivent N50-40
- for NEUMO BioControl D50 PN16 / 316L
- Slotted nut ≥ DN25 - DIN 11851
- Varivent ≥ DN25
- hygienic fitting with tension flange DN32
- Hygienice flange connection ≥ DN50 DIN11864-2
- SMS 1145 DN51
- SMS DN38
- Hygienic fittings ≥ DN33 - DIN11864-1-A
- Hyg. collar clamp adapter DN40PN40 DIN11864-3-A
- Hyg. clamp connection DIN11864-3-A; DN50 Rohr 53
- Swagelok VCR screwing
- Varivent G125
Indication
- Display/adjustment module PLICSCOM
- VEGADIS 81
- VEGADIS 82
- Display/adjustment module PLICSCOM
- VEGADIS 81
- VEGADIS 82
- Display/adjustment module PLICSCOM
- VEGADIS 81
- VEGADIS 82
- Display/adjustment module PLICSCOM
- VEGADIS 81
- VEGADIS 82
Selected Product